Blauberg Freshbox 60

  • Casing material: Coated steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • PM2.5 sensor: Optional
  • Temperature sensor: Built-in
Unit of measurement Freshbox 60
Minimum supply voltage V 100
Maximum supply voltage V 240
Power supply frequency Hz 50/60
Heat recovery efficiency, max % 79
Ingress protection rating - IP22
Blauberg Freshbox 60 45 60 2016
Trademark Blauberg
Model Freshbox 60
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-70.2 A+ -32 B -10.2 E
Type of ventilation unit Bidirectional
Type of drive installed Multi-speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery (%) 74
Maximum flow rate (m³/h) 60
Electric power input (W) 15.4
Reference flow rate (m³/s) 0.012
Specific power input (SPI) (W/(m³/h)) 0.229
Control typology Manual control
Mixing rate (%) 1
Airflow sensitivity at +20 Pa and -20 Pa (%) 0.4
The indoor/outdoor air tightness (m³/h) 0.5
Declared typology RVU BVU
Sound power level (dB(A)) 45
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
315 315 315
The annual heating saved (AHS) (kWh/a) Cold Average Warm
7819 3997 1807